- Copy the most recent
STP winsolvenz FLOW Connectorfrom\\kastpdat04\pde_auslieferungen\InputManagement\to the application server. - Stop winsolvenz.p4 server (
STP Server 8005). - Stop
STP winsolvenz.p4 FLOW Connector. - Create a backup of the winsolvenz.p4 database (you can find its name
in
C:\Program Files (x86)\STP AG\STP Server\STP.RemotingServer.exe.config). - Create backup of
C:\Program Files (x86)\STP AG\STP Server\STP.RemotingServer.exe.config. - Ensure that the following setting is set to false in
STP.RemotingServer.exe.configto disable the deprecated synchronization job:<add key="RefreshBeteiligtenCacheJobSettings_IsEnabled" value="false" />. - Add one of the following configuration snippets just before the
</appSettings>block inSTP.RemotingServer.exe.config, based on the SQL Server version:
- For SQL2014 or lower
\\kastpdat04\pde_auslieferungen\InputManagement\winsolvenzFlow Connector\winsolvenz.p4 10.13.130.2\STP.RemotingServer.exe (Auszug) - for_SQL_2014_or_lower.config - For SQL2016 or higher
\\kastpdat04\pde_auslieferungen\InputManagement\winsolvenzFlow Connector\winsolvenz.p4 10.13.130.2\STP.RemotingServer.exe (Auszug) - for_SQL_2016_or_higher.config
- Start winsolvenz.p4 server (
STP Server 8005). It may take some time to populate thetblAlleBeteiligtenCache2table with interested party data. - Delete the following file:
C:\ProgramData\STP AG\winsolvenz.FLOW.Connector\syncInterestedPartiesToFlowJobSettings.json. This file stores details of the last successful synchronization and will be recreated when the connector runs again. - Create a backup of the configuration file:
C:\Program Files (x86)\STP AG\STP winsolvenz.p4 FLOW Connector\appsettings.json. - Install the latest version of
STP winsolvenz.p4 FLOW Connector. - After installation, update the connection string placeholder in
appsettings.json:
"ConnectionStrings": {
"winsolvenz": "Server=<myServerAddress>;Database=<myDataBase>;User Id=<myUsername>;Password=<myPassword>;"
}NOTES:
- The correct settings can be found in
STP.RemotingServer.exe.config. - If using a SQL Server instance (server), replace the single
\with\\to avoid setup failures. - If SQL Server uses a self-signed certificate or one from an
untrusted CA, append:
TrustServerCertificate=True;to the connection string to prevent connection issues.
- Check the logs of the winsolvenz.p4 server in
C:\ProgramData\STP AG\WzServerand wait for confirmation that thetblAlleBeteiligtenCache2refresh job has completed. - Restart the
STP winsolvenz.p4 FLOW Connector.